QUELEN / Solutions / 26
Standard Hotel Room
A repeatable room package for a standard key: entry, bedside, climate and safety specified once and repeated across the floor plate.
Repeatable room package · sample-room approval · model-level schedule
Overview
A repeatable room package for a standard hotel key, with a sample room and a frozen model schedule.
SOLUTION / STANDARD ROOM
A repeatable package for a standard key.
The aim is not to specify every room separately. It is to define a standard key, prove it in one sample room, and repeat it with a controlled list of permitted variations.
- Room types are grouped into a small number of keys; each key gets one hardware schedule.
- The sample room proves fit, scene logic and cable/terminal identity before rollout.
- Variations such as accessible rooms, suites and connecting doors are listed, not left to site interpretation.
- Quantities, spares and replacement models are fixed with the schedule so procurement can compare offers.

Room package
A standard key is a zone map plus a model list. The same room logic should survive a change of supplier or a later replacement.
Entry
Card power and room status
- QL-KEY-002 — Card switch
- QL-IND-001 — Status board
- QL-SOS-001 — Emergency indicator
Bedside
Scene and guest charging
- QL-SCN-003-R4 — Scene board
- USB module — Charging
- Phone module — Hands-free option
Climate
Thermostat and lighting loads
- QL-THM-003 — Thermostat
- QL-DIM-400W-001 — Dimmer
- QL-FAN-300W-001 — Fan module
Safety
Sensing and emergency call
- QL-PIR-001 — PIR
- QL-SOS-002 — Relay board
- QL-STL-002 — Floor light
Architecture
A standard room still sits inside a building architecture. The room package must state what connects to the controller and what connects to the head-end.
Standard field set
The fixed devices used in every room of the key.
Room controller
One logic layer and scene set for the key.
Building interface
Status, alarms and remote operations for the floor.
Standard key — model map.
This is the level of detail a contractor needs to compare a room package without guessing what is included.
| Zone | Function | Example hardware | Selection note |
|---|---|---|---|
| Entry | Card power and status | QL-KEY-002 / QL-IND-001 | Verify existing wiring |
| Bedside | Scene and charging | QL-SCN-003-R4 / USB module | Panel gang and finish |
| Climate | HVAC and lighting | QL-THM-003 / QL-DIM-400W-001 | Load type and valve |
| Safety | Sensing and alarm | QL-PIR-001 / QL-SOS-002 | Code and voltage check |
FAQ
Can the standard key be used across different room sizes?
Yes, if the differences are defined as permitted variations. A suite or accessible room should have its own addendum, not an informal site change.
Do we need a sample room?
For a repeating hotel project, yes. It is the point where panel fit, scene logic, cabling and status behaviour are proven before volume orders.
How do you handle a change after approval?
The change is recorded against the key and the affected model list. It is not absorbed silently into the next batch.
Can we mix released and validation models in one room?
Only with a clear split in the schedule. Validation items are not quoted as released products and should not be treated as interchangeable.
What is the minimum order?
MOQ is 50–100 pcs per model, model-dependent. Mixed room packages are quoted from the schedule, with samples reviewed before the production batch.
Start a project review
Send the room schedule, target market and the released QL code or validation model you are planning with. The team replies with the model questions, document set and sample plan.